Detection of trace amounts of chromium (VI) using hydrogel coated Fiber Bragg grating PVN Kishore, MS Shankar, M Satyanarayana Sensors and Actuators B: Chemical 243, 626-633, 2017 | 47 | 2017 |
Hydrogel-coated fiber Bragg grating sensor for pH monitoring VNK Pabbisetti, SS Madhuvarasu Optical Engineering 55 (6), 066112-066112, 2016 | 27 | 2016 |
Stimulus responsive hydrogel-coated etched fiber Bragg grating for carcinogenic chromium (VI) sensing PVN Kishore, SS Madhuvarasu, S Moru Optical Engineering 57 (1), 017101-017101, 2018 | 11 | 2018 |
Study on polymer coated etched optical fiber for pH sensing PVN Kishore, MS Shanar, PV Rao, KY Goud, GS Rao International Conference on Fibre Optics and Photonics, T3A. 11, 2014 | 9 | 2014 |
Hydrogel coated fiber Bragg grating based pH sensor PVN Kishore, MS Shankar Frontiers in Optics, JW2A. 6, 2015 | 6 | 2015 |
Study of bridge weigh-in-motion using FBG sensors A Sravanthi, P Kishore, RLNS Prasad, PR Kumar International Conference on Fibre Optics and Photonics, Tu3G. 3, 2016 | 4 | 2016 |
Hydrogel coated fiber Bragg grating based chromium sensor PVN Kishore, SS Madhuvarasu, K Putha, S Moru, KV Gobi Optical sensing and detection IV 9899, 305-309, 2016 | 3 | 2016 |
Step-etched U-bent silica fiber optic probes–Design and optimum geometry for refractive index sensing AS Rajamani, H Manoharan, CG Danny, PVN Kishore, VVR Sai Sensors and Actuators A: Physical 342, 113615, 2022 | 2 | 2022 |
Design and development of a high sensitive low cost fiber optic refractometer P VN Kishore, M Sai Shankar, P Vengal Rao Photonic Fiber and Crystal Devices: Advances in Materials and Innovations in …, 2015 | 2 | 2015 |
Carcinogenic Chromium (VI) Sensing Using Transducing Characteristics of Fiber Bragg Grating and Physical Swelling of Hydrogel BM Pratima, PVN Kishore, J Ashok, M Satyanarayana, PK Reddy, ... Sensing and Imaging 23 (1), 27, 2022 | 1 | 2022 |
pH-responsive hydrogel coated Fiber bragg grating-based chemo mechanical sensor bioreactor applications VN Kishore P., S Shankar M. Proc. SPIE 10251, Biomedical Imaging and Sensing Conference, 1025120, 2017 | 1 | 2017 |
Characteristic study on double U-bent Plastic optical fiber based Refractometer PVA Hakeem, MS Shankar, PVN Kishore, S Ganesh, A Gupta, K Bedi International Conference on Fibre Optics and Photonics, Tu4A. 2, 2016 | 1 | 2016 |
Carcinogenic Chromium (VI) metal ion detection using hydrogel coated FBG PVN Kishore, MS Shankar International Conference on Fibre Optics and Photonics, Tu4A. 77, 2016 | 1 | 2016 |
Design and development of a refractometer using fiber solenoid A Gupta, MS Shankar, PVN Kishore, S Ganesh, PVA Hakeem International Conference on Fibre Optics and Photonics, W3A. 55, 2016 | 1 | 2016 |
Analyzing Characteristics of Sagnac Loop Interferometric Stress Sensor SR P.V.N.Kishore, M. Sai Shankar, P.Kishore IEEE Xplore, 1-3, 2013 | 1* | 2013 |
Metal–Organic Framework-Based Fiber Optic Sensor for Chromium (VI) Detection S Menon, SP Usha, H Manoharan, PVN Kishore, VVR Sai ACS sensors, 2023 | | 2023 |
Detection of copper by localized surface Plasmon resonance based fiber optic technique N Aruna, KC Mouli, PVN Kishore, BM Pratima, NR Rao, J Ashok Optical Sensors 2021 11772, 37-40, 2021 | | 2021 |
Multi U-bent cladded POF sensors for refractive index measurement PVN Kishore, N Aruna, BM Pratima, NR Rao, J Ashok Optical Sensors 2021 11772, 116-119, 2021 | | 2021 |
Carcinogenic Chromium (VI) sensing using fiber Bragg grating based on swelling of stimulus responsive hydrogel PVN Kishore, MS Shankar, VDR Pavan Frontiers in Optics, JW3A. 112, 2017 | | 2017 |
Comparative study on sensitivities of different geometries of Plastic optical fiber G Sunchu, MS Shankar, PVN Kishore, AH PV, A Gupta, G Divya International Conference on Fibre Optics and Photonics, Tu4A. 62, 2016 | | 2016 |