Review on vortex flowmeter—Designer perspective A Venugopal, A Agrawal, SV Prabhu Sensors and Actuators A: Physical 170 (1), 8-23, 2011 | 142 | 2011 |
Experimental visualization of sneezing and efficacy of face masks and shields V Arumuru, J Pasa, SS Samantaray Physics of Fluids 32 (11), 2020 | 82 | 2020 |
Influence of blockage and shape of a bluff body on the performance of vortex flowmeter with wall pressure measurement A Venugopal, A Agrawal, SV Prabhu Measurement 44 (5), 954-964, 2011 | 61 | 2011 |
Droplet fate, efficacy of face mask, and transmission of virus-laden droplets inside a conference room D Mirikar, S Palanivel, V Arumuru Physics of Fluids 33 (6), 2021 | 56 | 2021 |
Influence of blockage and upstream disturbances on the performance of a vortex flowmeter with a trapezoidal bluff body A Venugopal, A Agrawal, SV Prabhu Measurement 43 (4), 603-616, 2010 | 49 | 2010 |
Industrial fluid flow measurement using optical fiber sensors: A review H Gupta, V Arumuru, R Jha IEEE Sensors Journal 21 (6), 7130-7144, 2020 | 48 | 2020 |
Performance evaluation of piezoelectric and differential pressure sensor for vortex flowmeters A Venugopal, A Agrawal, SV Prabhu Measurement 50, 10-18, 2014 | 44 | 2014 |
A novel synthetic jet based heat sink with PCM filled cylindrical fins for efficient electronic cooling V Arumuru, K Rajput, R Nandan, P Rath, M Das Journal of Energy Storage 58, 106376, 2023 | 40 | 2023 |
Frequency Detection in Vortex Flowmeter for Low Reynolds Number using Piezoelectric Sensor and Installation Effects A Venugopal, A Agrawal, SV Prabhu Sensors and Actuators A: Physical, 2012 | 36 | 2012 |
Vortex shedding characteristics of a cylinder with a parallel slit placed in a circular pipe L Ordia, A Venugopal, A Agrawal, SV Prabhu Journal of Visualization, 1-13, 2016 | 27 | 2016 |
Double masking protection vs. comfort—A quantitative assessment V Arumuru, SS Samantaray, J Pasa Physics of Fluids 33 (7), 2021 | 23 | 2021 |
Breathing, virus transmission, and social distancing—An experimental visualization study V Arumuru, J Pasa, SS Samantaray, VS Varma AIP Advances 11 (4), 2021 | 22 | 2021 |
Note: A vortex cross-correlation flowmeter with enhanced turndown ratio A Venugopal, A Agrawal, SV Prabhu Review of Scientific Instruments 85 (6), 2014 | 22 | 2014 |
Vortex shedding optical flowmeter based on photonic crystal fiber V Arumuru, JN Dash, D Dora, R Jha Scientific Reports 9 (1), 8313, 2019 | 19 | 2019 |
Study on the design and performance of a bi-directional cone flowmeter K Borkar, A Venugopal, SV Prabhu Flow Measurement and Instrumentation 34, 151-159, 2013 | 19 | 2013 |
Experimental study of PCM based hybrid heat sink for electronic cooling N Rakesh, V Arumuru, P Rath, MK Das Journal of Enhanced Heat Transfer, 2022 | 18 | 2022 |
On the Linearity, Turndown Ratio and Shape of the Bluff Body for Vortex Flowmeter A Venugopal, Agrawal, SV Prabhu Measurement, 2019 | 15 | 2019 |
Improvement in the performance of the vortex flowmeter using contraction cone K Mohadikar, A Venugopal, A Agrawal, SV Prabhu Measurement 111, 316-332, 2017 | 15 | 2017 |
Evolution of flow structure from a coaxial synthetic jet S Panda, TB Gohil, V Arumuru International Journal of Mechanical Sciences 231, 107588, 2022 | 13 | 2022 |
Influence of Strouhal Number and Phase Difference on the Flow Behavior of a Synthetic Jet Array VA Jangyadatta Pasa, Samrendra Panda Physics of Fluids, 2022 | 13 | 2022 |