Follow
Praveen Kesavan
Title
Cited by
Cited by
Year
High performance conductivity monitoring instrument with pulsating sensor
P Sahoo, N Malathi, K Praveen, R Ananthanarayanan, AD Arun, N Murali, ...
Review of Scientific Instruments 81 (6), 2010
312010
A novel approach for high precision rapid potentiometric titrations: Application to hydrazine assay
P Sahoo, N Malathi, R Ananthanarayanan, K Praveen, N Murali
Review of Scientific Instruments 82 (11), 2011
282011
High-performance differential pressure monitoring devices using pulsating sensors for a sodium-cooled fast breeder reactor
K Praveen, MP Rajiniganth, AD Arun, R Ananthanarayanan, N Malathi, ...
Nuclear technology 176 (1), 127-137, 2011
132011
Implementation and performance comparison of digital filter in FPGA
K Thesni, K Praveen, L Srivani
2020 6th International Conference on Advanced Computing and Communication …, 2020
102020
Continuous-type liquid level measurement system using pulsating sensor
K Praveen, MP Rajniganth, AD Arun, P Sahoo, N Murali
2015 International Conference on Industrial Instrumentation and Control …, 2015
102015
A novel technique towards deployment of hydrostatic pressure based level sensor in nuclear fuel reprocessing facility
K Praveen, MP Rajiniganth, AD Arun, P Sahoo, SAV Satya Murty
Review of Scientific Instruments 87 (2), 2016
92016
A novel approach towards development of real time chemical dosimetry using pulsating sensor-based instrumentation
N Malathi, P Sahoo, K Praveen, N Murali
Journal of Radioanalytical and Nuclear Chemistry 298, 963-972, 2013
82013
Design, development and analysis of energy harvesting system for wireless pulsating sensors
K Praveen, M Pudipeddi, M Sivaramakrishna
2016 IEEE Annual India Conference (INDICON), 1-5, 2016
72016
Prognostics of electrolytic capacitors under inrush current overstress
K Praveen, N Kulshrestha, L Srivani, D Thirugnanamurthy, BK Panigrahi
2018 International Conference on Smart City and Emerging Technology (ICSCET …, 2018
52018
Failure of printed circuit boards during storage and service: leaked capacitors and white residue
A Ravi Shankar, K Praveen, SR Polaki, SC Vanithakumari, NG Krishna, ...
Journal of Materials Engineering and Performance 29, 6402-6411, 2020
22020
EMI/EMC qualification of differential pressure monitoring system for PFBR—A case study
K Praveen, AD Arun, M Sivaramakrishna
2016 International Conference on ElectroMagnetic Interference …, 2016
22016
Towards the design and development of a multinode wireless system for pulsating sensors
K Praveen, AD Arun, P Sahoo, N Murali, SAVS Murty
2013 International Conference on Advanced Electronic Systems (ICAES), 253-256, 2013
2013
NUCLEAR PLANT OPERATIONS AND CONTROL-High-Performance Differential Pressure Monitoring Devices Using Pulsating Sensors for a Sodium-Cooled Fast Breeder Reactor
K Praveen, MP Rajiniganth, AD Arun, R Ananthanarayanan, N Malathi, ...
Nuclear Technology 176 (1), 127, 2011
2011
Voltage-To-Frequency Conversion Simplifies Microvolt Measurements
K Praveen
Electronics Design, 2010
2010
The system can't perform the operation now. Try again later.
Articles 1–14