Follow
JAYANTA KUMAR BISWAS
JAYANTA KUMAR BISWAS
Ph.D
Verified email at nitp.ac.in
Title
Cited by
Cited by
Year
Effect of two-level pedicle-screw fixation with different rod materials on lumbar spine: A finite element study
∗ Jayanta Kumar Biswas a , Masud Rana b , Santanu Majumder a , Santanu Kumar ...
Journal of Orthopaedic Science 23 (2), 258-265, 2018
582018
Optimal selection of dental implant for different bone conditions based on the mechanical response
S Roy, M Das, P Chakraborty, JK Biswas, S Chatterjee, N Khutia, S Saha, ...
Acta of bioengineering and biomechanics 19 (2), 11-20, 2017
432017
Design of dental implant using design of experiment and topology optimization: A finite element analysis study
Y Gupta, R Iyer, VK Dommeti, E Nutu, M Rana, A Merdji, JK Biswas, S Roy
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2021
372021
Design factors of lumbar pedicle screws under bending load: A finite element analysis
AR Jayanta KumarBiswas, Tikeshwar Prasad Sahu, Masud Rana, Sandipan Roy ...
Biocybernetics and Biomedical Engineering 39 (1), 52-62, 2019
372019
Biomechanics of spinal implants—a review
P Jain, M Rana, JK Biswas, MR Khan
Biomedical Physics & Engineering Express 6 (4), 042002, 2020
272020
BIOMECHANICAL PERFORMANCE OF A MODIFIED DESIGN OF DYNAMIC CERVICAL IMPLANT COMPARED TO CONVENTIONAL BALL AND SOCKET DESIGN OF AN ARTIFICIAL INTERVERTEBRAL DISC IMPLANT: A …
SKKJKB SHAMBO BHATTACHARYA, SANDIPAN ROY, MASUD RANA, SREERUP BANERJEE
Journal of Mechanics in Medicine and Biology 19 (4), 1950017 (15 pages), 2019
272019
Stress distribution of overdenture using odd number implants – A finite element study
SR Rahul Kasani, Bhaskar Krishna Rama Sai Attili, Vamsi Krishna Dommeti, Ali ...
Journal of the Mechanical Behavior of Biomedical Materials 98 (2), 369-382, 2019
262019
EFFECTS OF CERVICAL DISC REPLACEMENT AND ANTERIOR FUSION FOR DIFFERENT BONE CONDITIONS: A FINITE ELEMENT STUDY
SM Jayanta Kumar Biswas, Sandipan Roy, Rururaj Pradhan, Masud Rana
International Journal for Multiscale Computational Engineering 17 (4), 411-427, 2019
232019
A comparison of rigid, semi-rigid and flexible spinal stabilization devices: a finite element study
JK Biswas, S Roy, M Rana, S Halder
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2019
222019
Motion analysis of lumbar vertebrae for different rod materials and flexible rod device – An experimental and finite element study
AR Masud Rana, Jayanta Kumar Biswas, Sandipan Roy, Palash Biswas, Santanu ...
Biocybernetics and Biomedical Engineering 40 (1), 2020
212020
Design and development of a novel expanding flexible rod device (FRD) for stability in the lumbar spine: a finite-element study
M Rana, S Roy, P Biswas, SK Biswas, JK Biswas
The International Journal of Artificial Organs 43 (12), 803-810, 2020
202020
Optimization of spinal implant screw for lower vertebra through finite element studies
J Biswas, S Karmakar, S Majumder, PS Banerjee, S Saha, ...
Journal of long-term effects of medical implants 24 (2-3), 99–108, 2014
192014
Design of patient specific spinal implant (pedicle screw fixation) using FE analysis and soft computing techniques
JK Biswas, S Dey, SK Karmakar, A Roychowdhury, S Datta
Current Medical Imaging 16 (4), 371-382, 2020
172020
Design of patient specific bone stiffness mimicking scaffold
M Rana, A Chaudhuri, JK Biswas, SI Karim, P Datta, SK Karmakar, ...
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2021
152021
Effect of single and multilevel artificial inter-vertebral disc replacement in lumbar spine: a finite element study
JK Biswas, M Rana, A Malas, S Roy, S Chatterjee, S Choudhury
The International Journal of Artificial Organs 45 (2), 193-199, 2022
142022
A comparative finite element analysis of artificial intervertebral disc replacement and pedicle screw fixation of the lumbar spine
Jayanta Kumar Biswas, Anindya Malas, Sourav Majumdar, Masud Rana
Computer Methods in Biomechanics and Biomedical Engineering 25, 2022
102022
Symbolic regression metamodel-based optimal design of patient-specific spinal implant (pedicle screw fixation)
JK Biswas, K Kalita, A Roychowdhury
Engineering with Computers 38 (2), 999-1014, 2022
92022
Artificial Intervertebral Disc Replacement to Provide Dynamic Stability to the Lumbar Spine: A Finite Element Study
JK Biswas, S Roy, S Majumder, SK Karmakar, S Saha, A Roychowdhurya.
Journal of Long-Term Effects of Medical Implants 28 (2), 1–9, 2018
92018
Measurement of strain in the rod for lumbar pedicle screw fixation: An experimental and finite element study
M Rana, JK Biswas, S Roy, N Ghosh, S Bhattacharya, SK Karmakar, ...
Biomedical Physics & Engineering Express 6 (6), 065035, 2020
82020
Effect of range of motion (ROM) for pedicle-screw fixation on lumbar spine with rigid and semi-rigid rod materials: A finite element study
AR Jayanta Kr. Biswas1, Masud Rana2 , Sandipan Roy3*, Santanu Majumder1 ...
IOP Conf. Series: Materials Science and Engineering 402 (2018), 012146, 2018
82018
The system can't perform the operation now. Try again later.