Selectin-like kinetics and biomechanics promote rapid platelet adhesion in flow: the GPIbα-vWF tether bond TA Doggett, G Girdhar, A Lawshé, DW Schmidtke, IJ Laurenzi, ... Biophysical journal 83 (1), 194-205, 2002 | 243 | 2002 |
High-shear stress sensitizes platelets to subsequent low-shear conditions J Sheriff, D Bluestein, G Girdhar, J Jesty Annals of biomedical engineering 38, 1442-1450, 2010 | 205 | 2010 |
Device Thrombogenicity Emulator (DTE)− Design optimization methodology for cardiovascular devices: A study in two bileaflet MHV designs M Xenos, G Girdhar, Y Alemu, J Jesty, M Slepian, S Einav, D Bluestein Journal of biomechanics 43 (12), 2400-2409, 2010 | 143 | 2010 |
Device thrombogenicity emulation: a novel method for optimizing mechanical circulatory support device thromboresistance G Girdhar, M Xenos, Y Alemu, WC Chiu, BE Lynch, J Jesty, S Einav, ... PloS one 7 (3), e32463, 2012 | 121 | 2012 |
Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation-optimized HeartAssist 5 VAD WC Chiu, G Girdhar, M Xenos, Y Alemu, JS Soares, S Einav, M Slepian, ... Journal of biomechanical engineering 136 (2), 021014, 2014 | 91 | 2014 |
The Syncardia™ total artificial heart: in vivo, in vitro, and computational modeling studies MJ Slepian, Y Alemu, JS Soares, RG Smith, S Einav, D Bluestein Journal of biomechanics 46 (2), 266-275, 2013 | 87 | 2013 |
Biological effects of dynamic shear stress in cardiovascular pathologies and devices G Girdhar, D Bluestein Expert review of medical devices 5 (2), 167-181, 2008 | 87 | 2008 |
Alterations in the intrinsic properties of the GPIbα–VWF tether bond define the kinetics of the platelet-type von Willebrand disease mutation, Gly233Val TA Doggett, G Girdhar, A Lawshe, JL Miller, IJ Laurenzi, SL Diamond, ... Blood 102 (1), 152-160, 2003 | 87 | 2003 |
In-vitro thrombogenicity assessment of flow diversion and aneurysm bridging devices G Girdhar, J Li, L Kostousov, J Wainwright, WL Chandler Journal of thrombosis and thrombolysis 40, 437-443, 2015 | 86 | 2015 |
Thrombogenicity of flow diverters in an ex vivo shunt model: effect of phosphorylcholine surface modification MW Hagen, G Girdhar, J Wainwright, MT Hinds Journal of neurointerventional surgery 9 (10), 1006-1011, 2017 | 78 | 2017 |
Design optimization of a mechanical heart valve for reducing valve thrombogenicity—a case study with ATS valve Y Alemu, G Girdhar, M Xenos, J Sheriff, J Jesty, S Einav, D Bluestein ASAIO journal 56 (5), 389-396, 2010 | 74 | 2010 |
Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices D Bluestein, S Einav, MJ Slepian Journal of biomechanics 46 (2), 338-344, 2013 | 68 | 2013 |
Thrombogenicity assessment of Pipeline Flex, Pipeline Shield, and FRED flow diverters in an in vitro human blood physiological flow loop model G Girdhar, A Andersen, E Pangerl, R Jahanbekam, S Ubl, K Nguyen, ... Journal of Biomedical Materials Research Part A 106 (12), 3195-3202, 2018 | 60 | 2018 |
Thrombogenic potential of Innovia polymer valves versus Carpentier-Edwards Perimount Magna aortic bioprosthetic valves TE Claiborne, G Girdhar, S Gallocher-Lowe, J Sheriff, YP Kato, L Pinchuk, ... ASAIO journal 57 (1), 26-31, 2011 | 51 | 2011 |
Electrically enhanced retrieval of material from vessel lumens G Girdhar, HK Nguyen US Patent 11,090,071, 2021 | 50 | 2021 |
Viscous flow simulation in a stenosis model using discrete particle dynamics: a comparison between DPD and CFD R Feng, M Xenos, G Girdhar, W Kang, JW Davenport, Y Deng, ... Biomechanics and modeling in mechanobiology 11, 119-129, 2012 | 47 | 2012 |
Membrane tether extraction from human umbilical vein endothelial cells and its implication in leukocyte rolling G Girdhar, JY Shao Biophysical Journal 87 (5), 3561-3568, 2004 | 46 | 2004 |
Simultaneous tether extraction from endothelial cells and leukocytes: observation, mechanics, and significance G Girdhar, JY Shao Biophysical Journal 93 (11), 4041-4052, 2007 | 43 | 2007 |
Thrombogenicity assessment of Pipeline, Pipeline Shield, Derivo and P64 flow diverters in an in vitro pulsatile flow human blood loop model G Girdhar, S Ubl, R Jahanbekam, S Thinamany, A Belu, J Wainwright, ... ENeurologicalSci 14, 77-84, 2019 | 39 | 2019 |
Hemodialysis catheter with improved side opening design S MacMeans, MR Sansoucy, G Girdhar, RM Braga US Patent 8,747,343, 2014 | 30 | 2014 |