Follow
Nikolay V. Vasilyev, MD
Title
Cited by
Cited by
Year
Tough adhesives for diverse wet surfaces
J Li, AD Celiz, J Yang, Q Yang, I Wamala, W Whyte, BR Seo, NV Vasilyev, ...
Science 357 (6349), 378-381, 2017
13272017
Soft robotic sleeve supports heart function
ET Roche, MA Horvath, I Wamala, A Alazmani, SE Song, W Whyte, ...
Science translational medicine 9 (373), eaaf3925, 2017
4132017
A blood-resistant surgical glue for minimally invasive repair of vessels and heart defects
N Lang, MJ Pereira, Y Lee, I Friehs, NV Vasilyev, EN Feins, K Ablasser, ...
Science translational medicine 6 (218), 218ra6-218ra6, 2014
3452014
A bioinspired soft actuated material
ET Roche, R Wohlfarth, JTB Overvelde, NV Vasilyev, FA Pigula, ...
Adv. Mater 26 (8), 1200-1206, 2014
2992014
Myeloperoxidase-generated oxidants modulate left ventricular remodeling but not infarct size after myocardial infarction
N Vasilyev, T Williams, ML Brennan, S Unzek, X Zhou, JW Heinecke, ...
Circulation 112 (18), 2812-2820, 2005
2262005
Concentric tube robot design and optimization based on task and anatomical constraints
C Bergeles, AH Gosline, NV Vasilyev, PJ Codd, PJ Del Nido, PE Dupont
IEEE Transactions on Robotics 31 (1), 67-84, 2015
2192015
Vascular endothelial growth factor prevents apoptosis and preserves contractile function in hypertrophied infant heart
I Friehs, R Barillas, NV Vasilyev, N Roy, FX McGowan, PJ del Nido
Circulation 114 (1_supplement), I-290-I-295, 2006
1862006
Comparison of biomaterial delivery vehicles for improving acute retention of stem cells in the infarcted heart
ET Roche, CL Hastings, SA Lewin, DE Shvartsman, Y Brudno, ...
Biomaterials 35 (25), 6850-6858, 2014
1852014
GPU based real-time instrument tracking with three-dimensional ultrasound
PM Novotny, JA Stoll, NV Vasilyev, PJ Del Nido, PE Dupont, TE Zickler, ...
Medical image analysis 11 (5), 458-464, 2007
1582007
Management of systemic right ventricular failure in patients with congenitally corrected transposition of the great arteries
AA Filippov, PJ Del Nido, NV Vasilyev
Circulation 134 (17), 1293-1302, 2016
1442016
Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools
AH Gosline, NV Vasilyev, EJ Butler, C Folk, A Cohen, R Chen, N Lang, ...
The International journal of robotics research 31 (9), 1081-1093, 2012
1192012
In Vitro Characterization of Bicuspid Aortic Valve Hemodynamics Using Particle Image Velocimetry
N Saikrishnan, CH Yap, NC Milligan, NV Vasilyev, AP Yoganathan
Annals of biomedical engineering 40, 1760-1775, 2012
1132012
Imaging artifacts of medical instruments in ultrasound‐guided interventions
J Huang, JK Triedman, NV Vasilyev, Y Suematsu, RO Cleveland, ...
Journal of Ultrasound in Medicine 26 (10), 1303-1322, 2007
1062007
Force tracking with feed-forward motion estimation for beating heart surgery
SG Yuen, DP Perrin, NV Vasilyev, PJ Del Nido, RD Howe
IEEE Transactions on Robotics 26 (5), 888-896, 2010
992010
Right ventricular papillary approximation
PJ Del Nido, H Yamauchi, NV Vasilyev, MJMN Pereira, ED O'cearbhaill
US Patent 10,420,645, 2019
982019
Sustained release of targeted cardiac therapy with a replenishable implanted epicardial reservoir
W Whyte, ET Roche, CE Varela, K Mendez, S Islam, H O’Neill, F Weafer, ...
Nature Biomedical Engineering 2 (6), 416-428, 2018
922018
Mitral annulus segmentation from 3D ultrasound using graph cuts
RJ Schneider, DP Perrin, NV Vasilyev, GR Marx, PJ Del Nido, RD Howe
IEEE transactions on Medical Imaging 29 (9), 1676-1687, 2010
922010
An implantable extracardiac soft robotic device for the failing heart: mechanical coupling and synchronization
CJ Payne, I Wamala, C Abah, T Thalhofer, M Saeed, D Bautista-Salinas, ...
Soft robotics 4 (3), 241-250, 2017
912017
Soft robotic ventricular assist device with septal bracing for therapy of heart failure
CJ Payne, I Wamala, D Bautista-Salinas, M Saeed, D Van Story, ...
Science Robotics 2 (12), eaan6736, 2017
802017
Real-time image-based rigid registration of three-dimensional ultrasound
RJ Schneider, DP Perrin, NV Vasilyev, GR Marx, PJ Del Nido, RD Howe
Medical image analysis 16 (2), 402-414, 2012
732012
The system can't perform the operation now. Try again later.
Articles 1–20