Follow
Eduardo Guy Perpétuo Bock
Eduardo Guy Perpétuo Bock
Laboratório de Bioengenharia e Biomateriais, Instituto Federal de Educação, Ciência e Tecnologia de
Verified email at ifsp.edu.br - Homepage
Title
Cited by
Cited by
Year
New centrifugal blood pump with dual impeller and double pivot bearing system: wear evaluation in bearing system, performance tests, and preliminary hemolysis tests
E Bock, A Ribeiro, M Silva, P Antunes, J Fonseca, D Legendre, J Leme, ...
Artificial Organs 32 (4), 329-333, 2008
752008
Computational fluid dynamics investigation of a centrifugal blood pump
D Legendre, P Antunes, E Bock, A Andrade, JF Biscegli, JP Ortiz
Artificial organs 32 (4), 342-348, 2008
522008
Cardiovascular simulator improvement: pressure versus volume loop assessment
J Fonseca, A Andrade, DEC Nicolosi, JF Biscegli, J Leme, D Legendre, ...
Artificial Organs 35 (5), 454-458, 2011
372011
Implantable centrifugal blood pump with dual impeller and double pivot bearing system: electromechanical actuator, prototyping, and anatomical studies
E Bock, P Antunes, T Leao, B Uebelhart, J Fonseca, J Leme, B Utiyama, ...
Artificial Organs 35 (5), 437-442, 2011
372011
A new model of centrifugal blood pump for cardiopulmonary bypass: design improvement, performance, and hemolysis tests
J Leme, J Fonseca, E Bock, C da Silva, BU da Silva, AE Dos Santos, ...
Artificial Organs 35 (5), 443-447, 2011
292011
Numerical Analyses for Low Reynolds Flow in a Ventricular Assist Device
G Lopes, E Bock, L Gómez
Artificial organs 41 (6), E30-E40, 2017
282017
Magnetic suspension of the rotor of a ventricular assist device of mixed flow type
O Horikawa, AJP De Andrade, I Da Silva, EGP Bock
Artificial organs 32 (4), 334-341, 2008
252008
Study of a centrifugal blood pump in a mock loop system
B Uebelhart, BU da Silva, J Fonseca, E Bock, J Leme, C da Silva, T Leão, ...
Artificial organs 37 (11), 946-949, 2013
242013
A new technique to control brushless motor for blood pump application
J Fonseca, A Andrade, DEC Nicolosi, JF Biscegli, D Legendre, E Bock, ...
Artificial organs 32 (4), 355-359, 2008
232008
Specification of supervisory control systems for ventricular assist devices
ACM Cavalheiro, DJ Santos Fo, A Andrade, JR Cardoso, O Horikawa, ...
Artificial Organs 35 (5), 465-470, 2011
212011
In vitro evaluation of multi‐objective physiological control of the centrifugal blood pump
T Leao, B Utiyama, J Fonseca, E Bock, A Andrade
Artificial Organs 44 (8), 785-796, 2020
192020
Mesh independency analyses and grid density estimation for ventricular assist devices in multiple reference frames simulations
GB Lopes, LC Gómez, EGP Bock
Technische Mechanik-European Journal of Engineering Mechanics 36 (3), 190-198, 2016
172016
Introductory tests to in vivo evaluation: Magnetic coupling influence in motor controller
E Bock, A Andrade, J Dinkhuysen, C Arruda, J Fonseca, J Leme, ...
ASAIO Journal 57 (5), 462-465, 2011
152011
Speed control of the implantable centrifugal blood pump to avoid aortic valve stenosis: Simulation and implementation
T Leão, J Fonseca, E Bock, R Sá, B Utiyama, E Drigo, J Leme, A Andrade
5th IEEE RAS/EMBS International Conference on Biomedical Robotics and …, 2014
132014
Single axis controlled hybrid magnetic bearing for left ventricular assist device: hybrid core and closed magnetic circuit
I da Silva, O Horikawa, JR Cardoso, FA Camargo, AJP Andrade, ...
Artificial Organs 35 (5), 448-453, 2011
132011
Investigation of MEMS as accelerometer sensor in an Implantable Centrifugal Blood Pump prototype
SS Neto, JRCS Sobrinho, C da Costa, TF Leão, S Senra, EGP Bock, ...
Journal of the Brazilian Society of Mechanical Sciences and Engineering 42 …, 2020
122020
Surface roughness of biomaterials and process parameters of titanium dioxide gritblasting for productivity enhancement
M Rodrigues, N Cruz, J Rocha, R Sá, E Bock
The Academic Society Journal 3 (2), 169-176, 2019
112019
A Ceramic Pivot Bearing Implantable Centrifugal Blood Pump
E Bock, T Leão, B Uebelhart, D Galantini, A Andrade, A Cavalheiro, ...
The International Journal of Artificial Organs 36 (8), 543, 2013
112013
Design of supervisory control system for ventricular assist device
A Cavalheiro, D Santos Fo, A Andrade, JR Cardoso, E Bock, J Fonseca, ...
Technological Innovation for Sustainability: Second IFIP WG 5.5/SOCOLNET …, 2011
112011
Left Ventricle Failure and Blood Flow Estimation for Centrifugal Blood Pumps
EGPB Bock, T Leão, J Fonseca, A Andrade
Journal of Mechanics Engineering and Automation 6 (3), 162-166, 2016
92016
The system can't perform the operation now. Try again later.