Follow
Dr. Manoj Kumar
Dr. Manoj Kumar
Verified email at barc.gov.in
Title
Cited by
Cited by
Year
An electrochemical method for the preparation of 63Ni source for the calibration of thermo luminescence dosimeter (TLD)
ADMV Manoj Kumar, J.Udhayakumar, Shyamala S. Gandhi
Applied Radiation and Isotopes, 67, 1042-1049, 2009
262009
“Development of technology for the large-scale preparation of 60Co polymer film source”
MV J. Udhayakumar, G.S. Pardeshi, Shyamala S. Gandhi, Rubel Chakravarty ...
Applied Radiation and Isotopes 66 (12), 1825-1829, 2008
162008
On the application of electrochemical techniques for the preparation of 57Co source core, encapsulation and quality evaluation for radiometric assay of nuclear fuel rods
MVVV Ashutosh Dash, Manoj Kumar, J.Udhayakumar, Shyamala S. Gandhi, A.K ...
Radiochimica Acta 99, 103-111, 2011
122011
Development of a 147Pm source for beta-backscatter thickness gauge applications
ADMV Manoj Kumar, J.Udhayakumar, J.Nuwad, Rakesh Sukla, C.G.S Pillai
Applied Radiation and Isotopes 69, 580-587, 2011
112011
Preparation of spherical 57Co source for the calibration of Intra- operative gamma probe
ADMV J.Udhayakumar Manoj Kumar, Shyamala S. Gandhi, B. S. Tomar
Applied radiation and Isotopes 70, 167-170, 2012
102012
Development of a micro electrochemical cell for in-situ deposition of 63Ni for use in electron capture detector (ECD) in gas chromatography
MV Ashutosh Dash, J.Udhayakumar, Manoj Kumar, Rakesh Shukla, Shyamala S ...
Radiochimica Acta 99, 733-741, 2011
92011
A novel method for the preparation of large-area 90Sr/90Y sources for the calibration of hand contamination monitors
AD Manoj Kumar, Shyamala S. Gandhi, Rubel Chakravarty, J. Nuwad, J. Udhayakumar
Applied radiation and Isotopes, 5-11, 2013
82013
Selective area chemical-deposition process: An innovative and facile route to prepare 147Pm source for dust monitors
ATAD Manoj Kumar, Rakesh Shukla, Shyamala S. Gandhi, J. Udhayakumar
Industrial & Engineering Chemistry Research, 11147-11156, 2012
72012
Preparation of 57Co point sources for the performance evaluation of nuclear imaging instruments
AD Sanjay Kumar Saxena, Manoj Kumar, Yogendra Kumar, J. Udhayakumar, Usha Pandey
Applied radiation and Isotopes, 12-17, 2013
52013
A novel and facile approach for the preparation of 133Ba source core, encapsulation and quality evaluation
AD Manoj Kumar, Shyamala S. Gandhi, J. Nuwad, J. Udhayakumar
Radiochimica Acta 101, 195-203, 2013
52013
An electrochemical technique to prepare 55Fe source for the calibration of the X-ray Detectors
AKTAD Manoj Kumar, Shyamala S. Gandhi, J. Udhayakumar, A. K. Satpati, R. Shukla
Radiochimica Acta 101, 185-193, 2013
52013
An electrochemical route to prepare planar 204Tl sources for the calibration of beta surface contamination monitors
JUAD S. S. Gandhi, M.Kumar, R. Chakravarty, J.Nuwad
Radiochimica Acta 101, 427-436, 2013
4*2013
A chemical deposition method to prepare circular planar 147Pm sources for the measurement of particulate emission in air
AD J.Udhayakumar, Shyamala S.Gandhi, Manoj Kumar
Applied radiation and Isotopes 79, 80-84, 2013
32013
Development of 57Co Pen Pointer Marker Source for Applications in Nuclear Medicine Procedures
AD Manoj Kumar, Shyamala S. Gandhi, J. Udhayakumar*
Nuclear and Radiochemistry Symposium(NUCAR), 462-463, 2015
1*2015
Quality assurance and classification performance testing of I-125-brachytherapy seeds
ADMV S. K. Saxena, Yogendra Kumar, Manoj Kumar
International Conference on Medical Physics( ICMP), 49-50, 2008
1*2008
Cadmium-109 Custom X-ray Source for Astronomical Applications
AD J.Udhayakumar, Manoj Kumar, Shyamala S. Gandhi
Nuclear and Radiochemistry Symposium(NUCAR), 464-465, 2015
2015
Development of Multi Dimensional 90Sr/90Y Thin Film Sources
AD Shyamala S. Gandhi, Manoj Kumar, J. Udhayakumar*
5th International Symposium on Material Chemistry, 334, 2014
2014
An elecrochemical pathway to prepare circular planar 90Sr/90Y source for the calibration of surface contamination monitor
AD Manoj Kumar, Shyamala S. Gandhi, J. Nuwad, J. Udhayakumar
J Radioanal Nucl Chem 302, 709-719, 2014
2014
Utilization of anodized aluminium surface as a substrate for the preparation of 147Pm source for dust monitor
JUAD Shyamala S. Gandhi, Manoj Kumar
ISEAC International Symposium cum Workshop on Electrochemistry, 156-159, 2011
2011
Development of a micro electrochemical cell for the deposition of 63Ni for use as an ionization source in electron capture detector (ECD) of gas chromatography
MKADMV J.Udhayakumar
7th International Conference on Isotopes (ICI), 128, 2011
2011
The system can't perform the operation now. Try again later.
Articles 1–20