Follow
Vaibhav R Mhatre
Vaibhav R Mhatre
Clinical Helpdesk Physics Support
Verified email at varian.com
Title
Cited by
Cited by
Year
Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array
DS Sharma, V Mhatre, M Heigrujam, K Talapatra, S Mallik
Journal of applied clinical medical physics 11 (4), 238-248, 2010
602010
Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array
DS Sharma, V Mhatre, M Heigrujam, K Talapatra, S Mallik
Journal of applied clinical medical physics 11 (4), 238-248, 2010
602010
Physical and dosimetric characteristic of high‐definition multileaf collimator (HDMLC) for SRS and IMRT
DS Sharma, PM Dongre, V Mhatre, M Heigrujam
Journal of applied clinical medical physics 12 (3), 142-160, 2011
392011
Dosimetric comparison of a-Si 1200 and a-Si 1000 electronic portal imager for intensity modulated radiation therapy (IMRT)
V Mhatre, S Pilakkal, P Chadha, K Talpatra
J Nucl Med Radiat Ther 9 (2), 1-6, 2018
172018
Evaluation of automated image registration algorithm for image-guided radiotherapy (IGRT)
SD Sharma, P Dongre, V Mhatre, M Heigrujam
Australasian physical & engineering sciences in medicine 35, 311-319, 2012
152012
Quality assurance for clinical implementation of an Optical Surface monitoring system
V Mhatre
IOSR Journal of Applied Physics (IOSR-JAP) 9 (Issue 6 Ver. II), 15-22, 2017
72017
Evaluation of ArcCHECK SNC machine QA tool for modern linear accelerator
VR Mhatre, PT Patwe
Int. J. Cancer Ther. Oncol 5, 2017
52017
Critical neurological structure sparing radiosurgery of vestibular schwannoma:Dosimetric comparison of different techniques and dose prescription methods Shamurailatpam
APK Dayananda Sharma,Pranav Chadha,Kaustav Talapatra,Vaibhav Mhatre
Journal of Cancer Research and Therapeutics 10 (1), 220, 2014
4*2014
Dosimetric Comparison of Two Linear Accelerator-Based Radiosurgery Systems for Intracranial Tumours with Rapidarc and Dynamic Conformal Arc Therapy.
VR Mhatre, P Chadha, R Chauhan, K Talapatra, AP Kumar
Iranian Journal of Medical Physics/Majallah-I Fīzīk-I Pizishkī-i Īrān 18 (5), 2021
22021
Dosimetric comparison of 6 MV flattening filter free and 6 MV stereotactic radiosurgery beam using 4 mm conical collimator for trigeminal neuralgia radiosurgery
VR Mhatre, P Chadha, AP Kumar, K Talapatra
Journal of Radiation Protection and Research 43 (3), 107-113, 2018
22018
EP-1533: Sensitivity of ArcCheck system to setup error using Perfect Pitch 6D couch
V Mhatre, P Patwe, P Dandekar
Radiotherapy and Oncology 119, S710, 2016
22016
SU‐GG‐T‐213: Portal Dosimetry for Pre‐Treatment Verification of IMRT Plan: A Comparison with 2D Ion Chamber Array
D Sharma, V Mhatre, M Heigrujam, K Talapatra, S Mallik
Medical Physics 37 (6Part18), 3234-3234, 2010
22010
EP-1341 Evaluation of tumor motion variability with and without abdominal compression plate in lung SBRT
K Talapatra, V Raturi, R Vadgaonkar, S Jadhav, P Chadha, V Mhatre, ...
Radiotherapy and Oncology 133, S734, 2019
12019
PO-0827: Hypofractionated image guided re-irradiation in head-neck cancers; an Indian experience
K Talapatra, P Chadha, M Deshpande, R Mistry, R Vadgaonkar, V Mhatre, ...
Radiotherapy and Oncology 152, S448, 2020
2020
PO-0848: Study of anatomical change during H&N RT with effect on delivered dose to spinal cord, parotid gland
A Srivastava, R Rathod, K Talapatra, A Sharma, V Mhatre, P Chadha, ...
Radiotherapy and Oncology 152, S457, 2020
2020
PO-0852: Can we ignore Submandibular gland constraints for Xerostomia prevention in Parotid sparing IMRT?
K George, K Talapatra, V Mhatre, P Chadha, MS Deshpande, R Mistry
Radiotherapy and Oncology 152, S459, 2020
2020
EP-1830 Dosimetric comparison of planning techniques in Radiosurgery for Arteriovenous Malformation
R Chauhan, V Mhatre, K Talapatra, P Chadha, P Shree, ...
Radiotherapy and Oncology 133, S993, 2019
2019
EP-2001 Efficacy of CBCT guided IMRT for Head and Neck cancers and its dosimetric impact on other structures.
K Talapatra, C Medichelme, R Chauhan, P Chadha, V Mhatre, V Muthu
Radiotherapy and Oncology 133, S1095, 2019
2019
A Comparative Dosimetric Study of High Definition (HD120) and Millennium (M120) Multi Leaf Collimators for Left-Sided Breast Cancer Using Four Different Radiotherapy Techniques
V Mhatre, S Pilakkal, V Manik, P Chadha, K Talpatra
MEDICAL PHYSICS 45 (6), E303-E304, 2018
2018
Comparison of ITV Delineation using Intensity Projections Methods for Eclipse and iPlan Treatment Planning System: A Phantom Study
VR Mhatre, P Shree, S Patil, R Chauhan, V Muthu, A Sharma, S Pilakkal, ...
2018
The system can't perform the operation now. Try again later.
Articles 1–20