Biswarup Mukherjee
Biswarup Mukherjee
Research Assistant Professor, Biomedical Imaging Laboratory, George Mason Univeristy
Verified email at gmu.edu
TitleCited byYear
An ophthalmic anesthesia training system using integrated capacitive and Hall effect sensors
B Mukherjee, B George, M Sivaprakasam
IEEE Transactions on Instrumentation and Measurement 63 (5), 1153-1162, 2014
102014
Evaluation of an ophthalmic anesthesia simulation system for regional block training
B Mukherjee, JV Venkatakrishnan, B George, M Sivaprakasam
Ophthalmology 122 (12), 2578-2580, 2015
52015
An intelligent ophthalmic regional anesthesia training system based on capacitive sensing
B Mukherjee, B George, M Sivaprakasam
2013 IEEE International Instrumentation and Measurement Technology …, 2013
52013
Low-power ultrasound imaging systems using time delay spectrometry
E Tarbox, N Akhlaghi, AS Dhawan, B Mukherjee, P Gammell, P Chitnis, ...
2017 IEEE International Ultrasonics Symposium (IUS), 1-4, 2017
32017
A multi-electrode electric field based sensing system for ophthalmic anesthesia training
B Mukherjee, B George, M Sivaprakasam
IEEE transactions on biomedical circuits and systems 9 (3), 431-440, 2014
32014
A hall effect sensor based syringe injection rate detector
B Mukherjee, B George, M Sivaprakasam
2012 Sixth International Conference on Sensing Technology (ICST), 450-453, 2012
32012
A capacitive array sensing based training system for ophthalmic anesthesia
B Mukherjee, B George, M Sivaprakasam, VJ Kumar, J Venkatakrishnan
2011 Fifth International Conference on Sensing Technology, 623-627, 2011
32011
Proprioceptive Sonomyographic Control: A novel method for intuitive and proportional control of multiple degrees-of-freedom for individuals with upper extremity limb loss
AS Dhawan, B Mukherjee, S Patwardhan, N Akhlaghi, G Diao, G Levay, ...
Scientific reports 9 (1), 9499, 2019
22019
An efficient capacitive sensing scheme for an ophthalmic regional anesthesia training system
B Mukherjee, B George, M Sivaprakasam
2013 35th Annual International Conference of the IEEE Engineering in …, 2013
22013
A syringe injection rate detector employing a dual Hall-effect sensor configuration
B Mukherjee, B George, M Sivaprakasam
2013 35th Annual International Conference of the IEEE Engineering in …, 2013
22013
A simple measurement scheme for multiple capacitors and its application to an ophthalmic anesthesia training system
B Mukherjee, B George, M Sivaprakasam
2015 IEEE International Instrumentation and Measurement Technology …, 2015
12015
Evaluation of the Role of Proprioception During Proportional Position Control Using Sonomyography: Applications in Prosthetic Control
S Patwardhan, AS Dhawan, B Mukherjee, M Alzamani, WM Joiner, ...
2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR …, 2019
2019
Sparsity Analysis of a Sonomyographic Muscle-Computer Interface
N Akhlaghi, A Dhawan, A Khan, B Mukherjee, G Diao, C Truong, S Sikdar
IEEE Transactions on Biomedical Engineering, 2019
2019
Ultrasound–Based Muscle Activity Sensing for Intuitive Proportional Control in Upper Extremity Amputees
B Mukherjee, AS Dhawan, S Patwardhan, J Majdi, RJ Holley, WM Joiner, ...
Archives of Physical Medicine and Rehabilitation 99 (10), e83-e84, 2018
2018
Ultrasound sensing-based intuitive proportional control: An evaluation study with upper-extremity amputees
A Dhawan, B Mukherjee, S Patwardhan, J Majdi, R Holley, W Joiner, ...
Annals of Physical and Rehabilitation Medicine 61, e471-e472, 2018
2018
System and method for a wearable medical simulator
P Tessier, M P. Ottensmeyer, J Gordon, B Mukherjee
US Patent WO 2016196658 A1, 2016
2016
An Eye Toward Improving: A new training approach in ophthalmic anesthesia provides qualitative and quantitative feedback.
B Mukherjee, M Sivaprakasam
IEEE pulse 6 (4), 20-25, 2015
2015
The system can't perform the operation now. Try again later.
Articles 1–17