Fundamentals of piezoelectricity A Arnau, D Soares Piezoelectric transducers and applications, 1-38, 2009 | 115 | 2009 |
Influence of thresholding procedures in ultrasonic grain noise reduction using wavelets JC Lazaro, JL San Emeterio, A Ramos, JL Fernandez-Marron Ultrasonics 40 (1-8), 263-267, 2002 | 103 | 2002 |
Noise reduction in ultrasonic NDT using undecimated wavelet transforms E Pardo, JL San Emeterio, MA Rodriguez, A Ramos Ultrasonics 44, e1063-e1067, 2006 | 98 | 2006 |
Ultrasonic flaw detection in NDE of highly scattering materials using wavelet and Wigner–Ville transform processing MA Rodrıguez, JL San Emeterio, JC Lázaro, A Ramos Ultrasonics 42 (1-9), 847-851, 2004 | 85 | 2004 |
Automatic system for dynamic control of resonance in high power and high Q ultrasonic transducers A Ramos-Fernandez, JA Gallego-Juarez, F Montoya-Vitini Ultrasonics 23 (4), 151-156, 1985 | 75 | 1985 |
Improvement in transient piezoelectric responses of NDE transceivers using selective damping and tuning networks A Ramos, JL San Emeterio, PT Sanz IEEE transactions on ultrasonics, ferroelectrics, and frequency control 47 …, 2000 | 68 | 2000 |
A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers I Bazán, M Vazquez, A Ramos, A Vera, L Leija Ultrasonics 49 (3), 358-376, 2009 | 54 | 2009 |
Dependence of pulser driving responses on electrical and motional characteristics of NDE ultrasonic probes A Ramos, JL San Emeterio, PT Sanz Ultrasonics 38 (1-8), 553-558, 2000 | 51 | 2000 |
Broad-band driving of echographic arrays using 10 ns-500 V efficient pulse generators A Ramos-Fernández, PT Sanz-Sánchez, FRM de Espinosa Ultrasonics 25 (4), 221-228, 1987 | 48 | 1987 |
Air-coupled ultrasonic resonant spectroscopy for the study of the relationship between plant leaves' elasticity and their water content D Sancho-Knapik, H Calas, JJ Peguero-Pina, AR Fernandez, ... IEEE transactions on ultrasonics, ferroelectrics, and frequency control 59 …, 2012 | 43 | 2012 |
Models for piezoelectric transducers used in broadband ultrasonic applications JL San Emeterio, A Ramos Piezoelectric transducers and applications, 97-116, 2008 | 35 | 2008 |
Ultrasonic characterization of granites obtained from industrial quarries of Extremadura (Spain) LM Del Río, F Lopez, FJ Esteban, JJ Tejado, M Mota, I González, ... Ultrasonics 44, e1057-e1061, 2006 | 35 | 2006 |
Evaluation of impedance matching schemes for pulse-echo ultrasonic piezoelectric transducers JLS Emeterio, A Ramos, PT Sanz, A Ruiz Ferroelectrics 273 (1), 297-302, 2002 | 34 | 2002 |
PSpice circuital modelling of ultrasonic imaging transceivers including frequency-dependent acoustic losses and signal distortions in electronic stages A Ramos, A Ruiz, JL San Emeterio, PT Sanz Ultrasonics 44, e995-e1000, 2006 | 31 | 2006 |
Changes in liver proteins of rats fed standard and high-fat and sucrose diets induced by fish omega-3 PUFAs and their combination with grape polyphenols according to … L Méndez, S Ciordia, MS Fernández, S Juárez, A Ramos, M Pazos, ... The Journal of Nutritional Biochemistry 41, 84-97, 2017 | 30 | 2017 |
Ultrasonic study of alteration processes in granites caused by freezing and thawing LM Del Roa, F Lopez, FJ Esteban, JJ Tejado, MI Mota, I González, ... 2005 IEEE Ultrasonics Symposium 1, 415-418, 2005 | 30 | 2005 |
Analysis of the ultrasonic field radiated by time-delay cylindrically focused linear arrays LG Ullate, A Ramos, JL San Emeterio IEEE transactions on ultrasonics, ferroelectrics, and frequency control 41 …, 1994 | 30 | 1994 |
Noninvasive Temperature Estimation in Oncology Hyperthermia Using Phase Changes in Pulse–Echo Ultrasonic Signals M Vázquez, A Ramos, L Leija, A Vera Japanese Journal of Applied Physics 45 (10R), 7991, 2006 | 29 | 2006 |
Noncontact ultrasonic spectroscopy applied to the study of polypropylene ferroelectrets TE Gómez Álvarez-Arenas, H Calás, JE Cuello, AR Fernández, M Muñoz Journal of Applied Physics 108 (7), 2010 | 27 | 2010 |
Modeling NDT piezoelectric ultrasonic transmitters JL San Emeterio, A Ramos, PT Sanz, A Ruız, A Azbaid Ultrasonics 42 (1-9), 277-281, 2004 | 27 | 2004 |