Induction motor inter turn fault detection using infrared thermographic analysis G Singh, TCA Kumar, VNA Naikan Infrared Physics & Technology 77, 277-282, 2016 | 128 | 2016 |
Detection of half broken rotor bar fault in VFD driven induction motor drive using motor square current MUSIC analysis G Singh, VNA Naikan Mechanical Systems and Signal Processing 110, 333-348, 2018 | 75 | 2018 |
Infrared thermography based diagnosis of inter-turn fault and cooling system failure in three phase induction motor G Singh, VNA Naikan Infrared Physics & Technology 87, 134-138, 2017 | 56 | 2017 |
Efficiency monitoring as a strategy for cost effective maintenance of induction motors for minimizing carbon emission and energy consumption G Singh, TCA Kumar, VNA Naikan Reliability Engineering & System Safety 184, 193-201, 2018 | 49 | 2018 |
Fault diagnosis of induction motor cooling system using infrared thermography G Singh, TCA Kumar, VNA Naikan 2016 IEEE 6th international conference on power systems (ICPS), 1-4, 2016 | 24 | 2016 |
Roping: Is it an optimum dewatering performance condition in a hydrocyclone? RK Dubey, G Singh, AK Majumder Powder technology 321, 218-231, 2017 | 16 | 2017 |
Effectiveness of vibration and current monitoring in detecting broken rotor bar and bearing faults in an induction motor TCA Kumar, G Singh, VNA Naikan 2016 IEEE 6th International Conference on Power Systems (ICPS), 1-5, 2016 | 16 | 2016 |
Effectiveness of Current Envelope analysis to detect broken rotor bar and inter turn faults in an inverter fed induction motor drive G Singh, CA Kumar, VNA Naikan 2015 international conference on power and advanced control engineering …, 2015 | 16 | 2015 |
PLC controlled elevator system G Singh, A Agarwal, RK Jarial, V Agarwal, M Mondal 2013 Students Conference on Engineering and Systems (SCES), 1-5, 2013 | 14 | 2013 |
Design of substation grounding grid using EDSA software M Mondal, RK Jarial, S Ram, G Singh 2013 Students Conference on Engineering and Systems (SCES), 1-6, 2013 | 14 | 2013 |
Effectiveness of vibration monitoring in the health assessment of induction motor TCA Kumar, G Singh, V Naikan International Journal of Prognostics and Health Management 6 (Special Issue …, 2015 | 11 | 2015 |
Sensitivity of rotor slot harmonics due to inter-turn fault in induction motors through vibration analysis TCA Kumar, G Singh, VNA Naikan 2018 International Conference on Power, Instrumentation, Control and …, 2018 | 10 | 2018 |
UV Spectrophotometer Based AI Techniques for Remnant Life Estimation of Power Transformers S Ram, AK Chandel, G Singh, M Mondal IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) 3 (3), 46-55, 2012 | 7 | 2012 |
Effective combination of motor fault diagnosis techniques A Gugaliya, G Singh, VNA Naikan 2018 International Conference on Power, Instrumentation, Control and …, 2018 | 5 | 2018 |
Broken rotor bar fault diagnosis in VFD driven induction motors by an improved vibration monitoring technique TCA Kumar, G SINGH, VNA Naikan International Journal of Performability Engineering 13 (1), 87, 2017 | 5 | 2017 |
Speed estimation of rotating machinery using generated harmonics G Singh, TCA Kumar, VNA Naikan Computers & Electrical Engineering 72, 420-430, 2018 | 4 | 2018 |
Modeling and simulation of indirect field oriented control of three phase induction motor using fuzzy logic controller G Singh, G Singh Int J Eng Res Technol (IJERT) 3 (8), 1126-1130, 2014 | 4 | 2014 |
PLC based automation of grain dryer G Singh, A Agarwal, RK Jarial 2013 International Conference on Control, Automation, Robotics and Embedded …, 2013 | 3 | 2013 |
A non intrusive methodology for bearing current detection in PWM inverter fed induction motor drive G Singh, TCA Kumar, VNA Naikan 2018 International Conference on Power, Instrumentation, Control and …, 2018 | 2 | 2018 |
Sequence Control of Grain Dryer Machine using PLC G Singh, RK Jarial, A Agarwal, S Ram, M Mondal, SK Dogra published in International organization of Scientific Research Journal of …, 0 | 2 | |