Follow
Kohji Mitsubayashi
Kohji Mitsubayashi
Verified email at tmd.ac.jp
Title
Cited by
Cited by
Year
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
MX Chu, K Miyajima, D Takahashi, T Arakawa, K Sano, S Sawada, ...
Talanta 83 (3), 960-965, 2011
2962011
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor
T Arakawa, Y Kuroki, H Nitta, P Chouhan, K Toma, S Sawada, S Takeuchi, ...
Biosensors and Bioelectronics 84, 106-111, 2016
2882016
A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques
H Kudo, T Sawada, E Kazawa, H Yoshida, Y Iwasaki, K Mitsubayashi
Biosensors and Bioelectronics 22 (4), 558-562, 2006
2842006
A flexible and wearable biosensor for tear glucose measurement
S Iguchi, H Kudo, T Saito, M Ogawa, H Saito, K Otsuka, A Funakubo, ...
Biomedical microdevices 9, 603-609, 2007
1922007
Analysis of metabolites in sweat as a measure of physical condition
K Mitsubayashi, M Suzuki, E Tamiya, I Karube
Analytica chimica acta 289 (1), 27-34, 1994
1731994
A wearable cellulose acetate-coated mouthguard biosensor for in vivo salivary glucose measurement
T Arakawa, K Tomoto, H Nitta, K Toma, S Takeuchi, T Sekita, S Minakuchi, ...
Analytical Chemistry 92 (18), 12201-12207, 2020
1602020
Gas-phase biosensor for ethanol
K Mitsubayashi, K Yokoyama, T Takeuchi, I Karube
Analytical Chemistry 66 (20), 3297-3302, 1994
1311994
Optical and electrochemical sensors and biosensors for the detection of quinolones
M Majdinasab, K Mitsubayashi, JL Marty
Trends in biotechnology 37 (8), 898-915, 2019
1242019
Trimethylamine biosensor with flavin-containing monooxygenase type 3 (FMO3) for fish-freshness analysis
K Mitsubayashi, Y Kubotera, K Yano, Y Hashimoto, T Kon, S Nakakura, ...
Sensors and Actuators B: Chemical 103 (1-2), 463-467, 2004
1232004
Combination of immunomagnetic separation with flow cytometry for detection of Listeria monocytogenes
K Hibi, A Abe, E Ohashi, K Mitsubayashi, H Ushio, T Hayashi, H Ren, ...
Analytica chimica acta 573, 158-163, 2006
992006
Bioelectronic sniffers for ethanol and acetaldehyde in breath air after drinking
K Mitsubayashi, H Matsunaga, G Nishio, S Toda, Y Nakanishi
Biosensors and Bioelectronics 20 (8), 1573-1579, 2005
992005
An acetone bio-sniffer (gas phase biosensor) enabling assessment of lipid metabolism from exhaled breath
M Ye, PJ Chien, K Toma, T Arakawa, K Mitsubayashi
Biosensors and Bioelectronics 73, 208-213, 2015
892015
Biomedical soft contact-lens sensor for in situ ocular biomonitoring of tear contents
MX Chu, T Shirai, D Takahashi, T Arakawa, H Kudo, K Sano, S Sawada, ...
Biomedical microdevices 13, 603-611, 2011
882011
Wireless enzyme sensor system for real-time monitoring of blood glucose levels in fish
H Endo, Y Yonemori, K Hibi, H Ren, T Hayashi, W Tsugawa, K Sode
Biosensors and Bioelectronics 24 (5), 1417-1423, 2009
832009
Optical-transparent and flexible glucose sensor with ITO electrode
K Mitsubayashi, Y Wakabayashi, S Tanimoto, D Murotomi, T Endo
Biosensors and Bioelectronics 19 (1), 67-71, 2003
772003
Electrical conductivity of tear fluid in healthy persons and keratoconjunctivitis sicca patients measured by a flexible conductimetric sensor
K Ogasawara, T Tsuru, K Mitsubayashi, I Karube
Graefe's archive for clinical and experimental ophthalmology 234, 542-546, 1996
761996
A bio-sniffer stick with FALDH (formaldehyde dehydrogenase) for convenient analysis of gaseous formaldehyde
K Mitsubayashi, G Nishio, M Sawai, T Saito, H Kudo, H Saito, K Otsuka, ...
Sensors and Actuators B: Chemical 130 (1), 32-37, 2008
742008
Wearable and flexible oxygen sensor for transcutaneous oxygen monitoring
K Mitsubayashi, Y Wakabayashi, D Murotomi, T Yamada, T Kawase, ...
Sensors and Actuators B: Chemical 95 (1-3), 373-377, 2003
732003
Cavitas sensors: Contact lens type sensors & mouthguard sensors
K Mitsubayashi, T Arakawa
Electroanalysis 28 (6), 1170-1187, 2016
712016
A wearable oxygen sensor for transcutaneous blood gas monitoring at the conjunctiva
S Iguchi, K Mitsubayashi, T Uehara, M Ogawa
Sensors and Actuators B: Chemical 108 (1-2), 733-737, 2005
632005
The system can't perform the operation now. Try again later.
Articles 1–20