A robust MART algorithm for tomographic applications D Mishra, K Muralidhar, P Munshi Numerical Heat Transfer: Part B: Fundamentals 35 (4), 485-506, 1999 | 92 | 1999 |
Performance of iterative tomographic algorithms applied to non-destructive evaluation with limited data PMV Subbarao, P Munshi, K Muralidhar Ndt & E International 30 (6), 359-370, 1997 | 82 | 1997 |
Error estimates for tomographic inversion P Munshi, RKS Rathore, KS Ram, MS Kalra Inverse Problems 7 (3), 399, 1991 | 70 | 1991 |
Error analysis of tomographic filters. I: Theory P Munshi NDT & E International 25 (4-5), 191-194, 1992 | 69 | 1992 |
Design of an isotopic CT scanner for two phase flow measurements AC De Vuono, PA Schlosser, FA Kulacki, P Munshi IEEE Transactions on Nuclear Science 27 (1), 814-820, 1980 | 61 | 1980 |
Error analysis of tomographic filters II: results P Munshi, RKS Rathore, KS Ram, MS Kalra NDT & E International 26 (5), 235-240, 1993 | 46 | 1993 |
Performance evaluation of fringe thinning algorithms for interferometric tomography D Mishra, K Muralidhar, P Munshi Optics and lasers in engineering 30 (3-4), 229-249, 1998 | 44 | 1998 |
Experimental study of Rayleigh–Benard convection at intermediate Rayleigh numbers using interferometric tomography D Mishra, K Muralidhar, P Munshi Fluid dynamics research 25 (5), 231, 1999 | 38 | 1999 |
Beam-hardening in simulated X-ray tomography K Ramakrishna, K Muralidhar, P Munshi NDT & E International 39 (6), 449-457, 2006 | 36 | 2006 |
Performance evaluation of iterative tomographic algorithms applied to reconstruction of a three-dimensional temperature field PMV Subbarao, P Munshi, K Muralidhar Numerical Heat Transfer 31 (3), 347-372, 1997 | 28 | 1997 |
Experimental aspects of the approximate error formula for tomographic reconstruction P Munshi, M Maisl, H Reiter Materials evaluation 55 (2), 1997 | 27 | 1997 |
An improved algorithm for beam-hardening corrections in experimental X-ray tomography V Vedula, P Munshi NDT & E International 41 (1), 25-31, 2008 | 25 | 2008 |
Analysis of high-speed CT scanners for non-medical applications PA Schlosser, AC De Vuono, FA Kulacki, P Munshi IEEE Transactions on Nuclear Science 27 (1), 788-794, 1980 | 25 | 1980 |
Gas hold-up in three phase co-current bubble columns S Kumar, RA Kumar, P Munshi, A Khanna Procedia Engineering 42, 782-794, 2012 | 24 | 2012 |
Tomographic KT-1 signature of phase-fraction distributions in multiphase bubble columns S Gulati, M Behling, P Munshi, A Luke, D Mewes Flow Measurement and Instrumentation 21 (3), 249-254, 2010 | 21 | 2010 |
Thermal stratification studies in a side heated water pool for advanced heavy water reactor applications A Gupta, V Eswaran, P Munshi, NK Maheshwari, PK Vijayan Heat and mass transfer 45 (3), 275-285, 2009 | 20 | 2009 |
Analysis of dynamic bias error in X-ray tomographic reconstructions of a three-phase flow system S Shakya, P Munshi, M Behling, A Luke, D Mewes International journal of multiphase flow 58, 57-71, 2014 | 19 | 2014 |
Application of fractal dimension for nondestructive testing V Bhatt, P Munshi, JK Bhattacharjee Materials evaluation 49 (11), 1414-1418, 1991 | 17 | 1991 |
Studies on a 300 k pixel detector telescope P Middelkamp, F Antinori, D Barberis, KH Becks, H Beker, W Beusch, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 1996 | 16 | 1996 |