Sensitivity analysis of design parameters and optimal design for zero/low energy buildings in subtropical regions
H Li, S Wang, H Cheung
Applied Energy 228, 1280-1291, 2018
1302018
A simplified power consumption model of information technology (IT) equipment in data centers for energy system real-time dynamic simulation
H Cheung, S Wang, C Zhuang, J Gu
Applied Energy 222, 329-342, 2018
782018
Optimal control strategy of central air-conditioning systems of buildings at morning start period for enhanced energy efficiency and peak demand limiting
R Tang, S Wang, K Shan, H Cheung
Energy 151, 771-781, 2018
632018
Hybrid model-based and data-driven fault detection and diagnostics for commercial buildings
S Frank, M Heaney, X Jin, J Robertson, H Cheung, R Elmore, G Henze
National Renewable Energy Lab.(NREL), Golden, CO (United States), 2016
552016
Simulation of fault impacts for vapor compression systems by inverse modeling. Part I: Component modeling and validation
H Cheung, JE Braun
HVAC&R Research 19 (7), 892-906, 2013
542013
Simulation of Fault Impacts for Vapor Compression Systems by Inverse Modeling Part II: System Modeling and Validation
H Cheung, JE Braun
HVAC&R Research 19 (7), 907-921, 2013
522013
Empirical modeling of the impacts of faults on water-cooled chiller power consumption for use in building simulation programs
H Cheung, JE Braun
Applied Thermal Engineering 99, 756-764, 2016
372016
Reliability and availability assessment and enhancement of water-cooled multi-chiller cooling systems for data centers
H Cheung, S Wang
Reliability Engineering & System Safety 191, 106573, 2019
292019
Development of Fault Models for Hybrid Fault Detection and Diagnostics Algorithm
H Cheung, JE Braun
National Renewable Energy Laboratory, 2015
29*2015
Optimal design of data center cooling systems concerning multi-chiller system configuration and component selection for energy-efficient operation and maximized free-cooling
H Cheung, S Wang
Renewable Energy 143, 1717-1731, 2019
282019
Component-based, gray-box modeling of ductless multi-split heat pump systems
H Cheung, JE Braun
International Journal of Refrigeration 38, 30-45, 2014
242014
Performance comparisons for variable-speed ductless and single-speed ducted residential heat pumps
H Cheung, JE Braun
International Journal of Refrigeration 47, 15-25, 2014
222014
Validation of a Fault-Modeling Equipped Vapor Compression System Model Using a Fault Detection and Diagnostics Evaluation Tool
DP Yuill, H Cheung, JE Braun
Proceedings of the 15th International Refrigeration and Air Conditioning …, 2014
212014
A general method for calculating the uncertainty of virtual sensors for packaged air conditioners
H Cheung, JE Braun
International Journal of Refrigeration 63, 225-236, 2016
182016
A Monte Carlo Simulation approach for the modeling of free-molecule squeeze-film damping of flexible microresonators
R Leung, H Cheung, H Gang, W Ye
Microfluidics and nanofluidics 9, 809-818, 2010
182010
Evaluation of Fault Detection and Diagnostics Tools by Simulation Results of Multiple Vapor Compression Systems
DP Yuill, H Cheung, JE Braun
Proceedings of the 15th International Refrigeration and Air Conditioning …, 2014
17*2014
A comparison of the effect of empirical and physical modeling approaches to extrapolation capability of compressor models by uncertainty analysis: A case study with common semi …
H Cheung, S Wang
International Journal of Refrigeration 86, 331-343, 2018
162018
A method to calculate uncertainty of empirical compressor maps with the consideration of extrapolation effect and choice of training data
H Cheung, O Sarfraz, CK Bach
Science and Technology for the Built Environment 24 (7), 743-758, 2018
132018
Minimizing data collection for field calibration of steady-state virtual sensors for HVAC equipment
H Cheung, JE Braun
International Journal of Refrigeration 69, 96-105, 2016
122016
Virtual Power Consumption and Cooling Capacity Virtual Sensors for Rooftop Units
H Cheung, JE Braun
Proceedings of the 15th International Refrigeration and Air Conditioning …, 2014
122014