cyril riddell
cyril riddell
ge healthcare
Verified email at ge.com
Title
Cited by
Cited by
Year
Noise reduction in oncology FDG PET images by iterative reconstruction: a quantitative assessment
C Riddell, RE Carson, JA Carrasquillo, SK Libutti, DN Danforth, ...
Journal of Nuclear Medicine 42 (9), 1316-1323, 2001
1192001
A linear wavelet filter for parametric imaging with dynamic PET
FE Turkheimer, JAD Aston, RB Banati, C Riddell, VJ Cunningham
IEEE Transactions on Medical Imaging 22 (3), 289-301, 2003
972003
An automatic classification technique for attenuation correction in positron emission tomography
V Bettinardi, E Pagani, MC Gilardi, C Landoni, C Riddell, G Rizzo, ...
European journal of nuclear medicine 26 (5), 447-458, 1999
961999
The watershed algorithm: a method to segment noisy PET transmission images
C Riddell, P Brigger, RE Carson, SL Bacharach
IEEE Transactions on Nuclear Science 46 (3), 713-719, 1999
731999
Design and development of C-arm based cone-beam CT for image-guided interventions: initial results
GH Chen, J Zambelli, BE Nett, M Supanich, C Riddell, B Belanger, ...
Medical Imaging 2006: Physics of Medical Imaging 6142, 614210, 2006
492006
Method and device for imaging with reorientation of an object
L Launay, YLM Trousset, C Riddell
US Patent 7,170,533, 2007
482007
Noninvasive estimation of the aorta input function for measurement of tumor blood flow with [/sup 15/O] water
W Watabe, MA Channing, C Riddell, F Jousse, SK Libutti, JA Carrasquillo, ...
IEEE transactions on medical imaging 20 (3), 164-174, 2001
452001
Rectification for cone-beam projection and backprojection
C Riddell, Y Trousset
IEEE Transactions on Medical Imaging 25 (7), 950-962, 2006
382006
Biases affecting the measurements of tumor-to-background activity ratio in PET
M Soret, C Riddell, S Hapdey, I Buvat
IEEE Transactions on Nuclear Science 49 (5), 2112-2118, 2002
342002
The approximate inverse and conjugate gradient: non-symmetrical algorithms for fast attenuation correction in SPECT
C Riddell, B Bendriem, MH Bourguignon, JP Kernevez
Physics in Medicine & Biology 40 (2), 269, 1995
331995
Compressed sensing based 3D tomographic reconstruction for rotational angiography
H Langet, C Riddell, Y Trousset, A Tenenhaus, E Lahalle, G Fleury, ...
International Conference on Medical Image Computing and Computer-Assisted …, 2011
192011
Diffusion regularization for iterative reconstruction in emission tomography
C Riddell, H Benali, I Buvat
IEEE Transactions on Nuclear Science 51 (3), 712-718, 2004
172004
Iterative reconstruction of SPECT data with adaptive regularization
C Riddell, I Buvat, A Savi, MC Gilardi, F Fazio
IEEE Transactions on Nuclear Science 49 (5), 2350-2354, 2002
142002
Novel C-arm based cone-beam CT using a source trajectory of two concentric arcs
J Zambelli, BE Nett, S Leng, C Riddell, B Belanger, GH Chen
Medical Imaging 2007: Physics of Medical Imaging 6510, 65101Q, 2007
132007
Evaluation of pre‐and post‐reconstruction count‐dependent Metz filters for brain PET studies
J Varga, V Bettinardi, MC Gilardi, C Riddell, I Castiglioni, G Rizzo, F Fazio
Medical physics 24 (9), 1431-1440, 1997
121997
Frequency weighted least squares reconstruction of truncated transmission SPECT data
C Riddell, A Savi, MC Gilardi, F Fazio
IEEE Transactions on Nuclear Science 43 (4), 2292-2298, 1996
121996
Compressed‐sensing‐based content‐driven hierarchical reconstruction: Theory and application to C‐arm cone‐beam tomography
H Langet, C Riddell, A Reshef, Y Trousset, A Tenenhaus, E Lahalle, ...
Medical physics 42 (9), 5222-5237, 2015
112015
Compressed sensing dynamic reconstruction in rotational angiography
H Langet, C Riddell, Y Trousset, A Tenenhaus, E Lahalle, G Fleury, ...
International Conference on Medical Image Computing and Computer-Assisted …, 2012
102012
Circular tomosynthesis implemented with a clinical interventional flat-panel based C-Arm: initial performance study
BE Nett, J Zambelli, C Riddell, B Belanger, GH Chen
Medical Imaging 2007: Physics of Medical Imaging 6510, 65101N, 2007
102007
Process and apparatus for calibration of a radiological imaging device
J Pescatore, C Riddell, Y Trousset, R Vaillant
US Patent 7,066,646, 2006
92006
The system can't perform the operation now. Try again later.
Articles 1–20